Positive mixed lymphocyte culture test result due to hla-dp mismatch HLA-DP uyumsuzluǧuna baǧlı mikst lenfosit kültür testindeki pozitiflik
Balkan Medical Journal, cilt.28, sa.2, ss.224-226, 2011 (Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 28 Sayı: 2
- Basım Tarihi: 2011
- Doi Numarası: 10.5174/tutfd.2009.02852.1
- Dergi Adı: Balkan Medical Journal
- Derginin Tarandığı İndeksler: Scopus
- Sayfa Sayıları: ss.224-226
- Anahtar Kelimeler: HLA-DP, Mixed lymphocyte culture, Stem cell transplantation
- Trakya Üniversitesi Adresli: Evet
Özet
Graft Versus Host Disease (GVHD) remains a major cause of morbidity and mortality in allogeneic stem cell transplantation (SCT). The MLC assay has been generally accepted as a standard test for determining HLA-D region compatibility. In this study, the MLC test has been carried out on the related recipient-donor couple who were prepared for allogeneic SCT and were found to be matched for HLA-A, -B, -Cw, DR, DQ but not for -DP. The result of the MLC test was positive. We observed that HLA-DP mismatch was responsible for the increased proliferation values in MLC test. © Trakya University Faculty of Medicine.